Spec Smiths Detection SCANVAN 8585 Gilardoni FEP ME 975 SCANTR C
Tunnel
Tunnel Width (mm) 853 906
Tunnel Height (mm) 856 758
Conveyor
Conveyor Height (mm) 300 N/A
Conveyor Speed (m/s) 0.2 0.2
Load Capacity (kg) 200 160
Generator
X-ray Voltage (kV) 160 160
X-ray Current (mA) N/A 1
Generator(s) 1 1
Cooling Type Hermetically sealed oil bath Oil bath and air
Imaging
View(s) Single Single
Performance
Wire Resolution (mm) 38 41
Steel Penetration (mm) 31 35
Mechanical
Footprint (L×W×H) (mm) N/A 6538 x 1990 x 3000
Electrical
Power External power supply 220 - 240 VAC +10% / -15%, 50 or 60 Hz ± 3 Hz Connection to main with roll away cable
Software
Software / OS Linux Linux
Options
Options Power generator driven by the vehicle engine, Power generator with own diesel engine, Stronger air conditioner, Sun-Blind, Monitor options, Rear view system, Intercom system, Video monitoring system, Printer, Console with shelf, Floor heating for operators cabin, Auxiliary heating for operators cabin, Outside lighting, Further options on request ADS, AIMS, TIP, Smart-card login
Features SCANVAN 8585 FEP ME 975 SCANTR C
Features Mobile
flexible system
Insulated body
Powerful X-ray generator (160 kV cp)
Penetration up to 31 mm steel (typical)
Film safe up to ISO 1600 / 33 DIN
Integrated power generator (option)
Air-conditioner
Rapid heater
Motorized conveyor at input side
Heavy duty roller conveyor at output
Equipped operator space with control desk
operator chair
monitor
keyboard
monitor LCD widescreen
Duty cycle: 100%
Beam orientation: diagonal downwards
Leakage dose at 10cm: < 1.0µSv/h (0.1mR/h)
Film safety guaranteed up to ISO 1600/33 DIN